Fast heating tube test of MCX-8100 EMTAP 41 Test
Abstract
The EMTAP 41 fast heating tube test has been carried out during STANAG 4170 qualification of
MCX-8100. Seven tubes have been tested and all open up by a burning or degree 1 reaction
with no fragmentation. The recovered tubes may be divided into two groups. Four tubes have
one longitudinal crack in the center of the body. These reacted after 124+5 seconds at an outer
tube surface temperature of 500+33oC. The three remaining tubes, still in one piece, have two
or more longitudinal cracks in the body. For these tubes the time to reaction is 154+12 seconds
with an outer tube surface temperature of 390+25oC.
MCX-8100 gives a degree 1 or burn reaction for all seven tested tubes in the fast heating test.
This shows a mild reaction of the MCX-8100 composition when exposed to the fast heating
threat. For munitions filled with MCX-8100 the possibility to achieve IM properties should be
good when exposed to thermal threats. EMTAP 41 hurtig oppvarmingstest har blitt gjennomført for kvalifisering av komposisjonen MCX-
8100. Sju rør er testet, og alle gir en brann eller grad 1 reaksjon. Ingen av rørene fragmenterer i
løpet av reaksjonen. Rørene åpnes opp og forblir i et stykke, men kan imidlertid deles i to
grupper. Fire rør har en sprekk i lengderetningen, og reagerer etter 124+5 sekunder med en
gjennomsnittlig ytre overflatetemperatur på 500+33oC. De resterende tre rørene, fremdeles i ett
stykke, har flere sprekker med deler som er i ferd med å bli til fragmenter. Disse rørene reagerer
etter 154+12 sekunder med en gjennomsnittlig ytre overflatetemperatur på 390+25oC.
MCX-8100 gir grad 1 reaksjon eller brann for alle sju testede rør i hurtig oppvarmingstest. Utfra
dette resultatet kan vi forvente at også ammunisjon med MCX-8100-fylling vil gi en mild
reaksjon stilt overfor en branntrussel.