dc.contributor.author | Fykse, Else-Marie | |
dc.contributor.author | Nilsen, Trine | |
dc.contributor.author | Nielsen, Agnete Dessen | |
dc.contributor.author | Tryland, Ingun | |
dc.contributor.author | Delacroix, Stephanie | |
dc.contributor.author | Blatny, Janet Martha | |
dc.date.accessioned | 2017-10-31T12:04:48Z | |
dc.date.accessioned | 2017-11-01T09:05:51Z | |
dc.date.available | 2017-10-31T12:04:48Z | |
dc.date.available | 2017-11-01T09:05:51Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Fykse E, Nilsen T, Nielsen AD, Tryland I, Delacroix S, Blatny JM. Real-time PCR and NASBA for rapid and sensitive detection of Vibrio cholerae in ballast water. Marine Pollution Bulletin. 2012;64(2):200-206 | en_GB |
dc.identifier.uri | http://hdl.handle.net/20.500.12242/769 | |
dc.identifier.uri | https://ffi-publikasjoner.archive.knowledgearc.net/handle/20.500.12242/769 | |
dc.description | Fykse, Else-Marie; Nilsen, Trine; Nielsen, Agnete Dessen; Tryland, Ingun; Delacroix, Stephanie; Blatny, Janet Martha.
Real-time PCR and NASBA for rapid and sensitive detection of Vibrio cholerae in ballast water. Marine Pollution Bulletin 2012 ;Volum 64.(2) s. 200-206 | en_GB |
dc.description.abstract | Transport of ballast water is one major factor in the transmission of aquatic organisms, including pathogenic bacteria. The IMO-guidelines of the Convention for the Control and Management of Ships’ Ballast Water and Sediments, states that ships are to discharge <1 CFU per 100 ml ballast water of toxigenic Vibrio cholerae, emphasizing the need to establish test methods. To our knowledge, there are no methods sensitive and rapid enough available for cholera surveillance of ballast water. In this study real-time PCR and NASBA methods have been evaluated to specifically detect 1 CFU/100 ml of V. cholerae in ballast water. Ballast water samples spiked with V. cholerae cells were filtered and enriched in alkaline peptone water before PCR or NASBA detection. The entire method, including sample preparation and analysis was performed within 7 h, and has the potential to be used for analysis of ballast water for inspection and enforcement control. | en_GB |
dc.language.iso | en | en_GB |
dc.subject | Ballast vann | |
dc.subject | Bakterier | |
dc.subject | Deteksjon | |
dc.title | Real-time PCR and NASBA for rapid and sensitive detection of Vibrio cholerae in ballast water | en_GB |
dc.type | Article | en_GB |
dc.date.updated | 2017-10-31T12:04:48Z | |
dc.identifier.cristinID | 875200 | |
dc.identifier.cristinID | 875200 | |
dc.identifier.doi | 10.1016/j.marpolbul.2011.12.007 | |
dc.source.issn | 0025-326X | |
dc.source.issn | 1879-3363 | |
dc.type.document | Journal article | |
dc.relation.journal | Marine Pollution Bulletin | |